Skip to content
PDFUAChecker

Matterhorn Checkpoint 30: XObjects

Reusable page content (XObjects) must not hide content from the structure: no reference XObjects, and tagged form XObjects may be used only once.

Failure conditions

IDWhat failsISO 14289-1Test
30-001The file contains a reference XObject.7.20Machine-testable · checked by our engine
30-002A form XObject with marked content (MCIDs) is drawn more than once.7.20Machine-testable

Conditions summarised from the Matterhorn Protocol 1.1 (PDF Association). Our checker decides 30-001 directly.

How to fix it

In Word

  1. Rare in Word exports.
  2. If flagged, re-export from Word directly rather than through a PDF printer.
  3. Re-check.

In InDesign

  1. Avoid placing PDFs that were themselves tagged; place the source artwork.
  2. Re-export.
  3. Re-check.

In Acrobat

  1. Use Preflight fixups to flatten reference XObjects.
  2. Retag the affected content.
  3. Save.

How to verify it

Our checker fails reference XObjects. The repeated-MCID test needs a content-stream pass (veraPDF covers it).

Check your PDF against PDF/UA-1.

Check your PDF →

What automated checking can't decide here

Related checkpoints

Our methodology explains how results are produced.